When connecting «Skypatrol ST8050» with TurnKey profile to Wialon obey the following rules:
1. When configuring messages in Add TurnKey profile the following fields are mandatory: «message count to message», «time to message», «modem ID to modem-originated message». Field «modem ID» value must be indicated in the first field «Unique ID» in unit properties in Wialon. Unlike fields decsribed below these fields need not be indicated in option «Messages format:» in unit properties in Wialon in «Device configuration» tab.
2. Other fields are optional. If they are selected when configuring messages in TurnKey profile they must be indicated in option «Messages format:» in unit properties in Wialon in «Device configuration» tab.
Add TurnKey | Parameter name in option «Messages format:» |
latitude to message | lat |
longitude to message | lon |
altitude to message | alt |
speed to message | spd |
heading to message | hdn |
DIOs to message | io |
Analog 0 to message | adc0 |
Analog 1 to message | adc1 |
Battery Power to message | bat |
PULSE COUNT data to message
or
CAN data to message | cnters
or
can |
These fields must be written in option "Messages format:" in the aforeindicated order.
ATTENTION!!! The order of parameters can not be changed.
«Messages format:» option content example when all the fields and impulse counters are selected:
lat,lon,alt,spd,hdn,io,adc0,adc1,bat,cnters
«Register raw data» option activation in «Device configuration» tab allows to view raw data received from the device.
TurnKey profile settings can be handled both by RS232 interface or by sending commands via SMS or Iridium.