Carrier LYNX API

Carrier LYNX API
Fabricant: Carrier
Forum de discussion

Nombre des unités

20
En ligne
46
Nombre total

Afin d'identifier le boîtier Carrier LYNX API les détails suivants sont à utiliser dans les réglages de l'unité sur Wialon :

Type du boîtier GPS: Carrier LYNX API
ID unique: custom

46 unités Carrier LYNX API connectées au le centre de données Wialon — Ça fait 0.05% de nombre total des boîtiers GPS connectés.

Le diagramme ci-dessous représente la dynamique des connexions dans le centre de données Wialon au cours des 30 derniers jours:

Nom du paramètre Description Unités
pwr_on

powerStatus field in LYNX API

Transport Refrigeration Unit Power Status (On or Off)

total_hours

switchOnHours field in LYNX API

The total accumulated hours that the Transport Refrigeration Unit has been turned on

eng_hours

engineRunHours field in LYNX API

The total accumulated hours that the Transport Refrigeration Unit has been running on its engine

tru_status

truStatus field in LYNX API

Overall Status of the Transport Refrigeration Unit

The following values are allowed:OFF, ON

hours_standby

standByHours field in LYNX API

The total accumulated hours that the Transport Refrigeration Unit has been running on stand by, or electric, power

movement_status

movementStatus field in LYNX API

Indicates if the unit is moving or not

eng_power_mode

enginePowerMode field in LYNX API

Transport Refrigeration Unit Power Source (Engine or Standby)

The following values are allowed:Standby, Engine

eng_ctrl_mode

engineControlMode field in LYNX API

Transport Refrigeration Unit Control Mode

The following values are allowed:Continuous, Start/Stop

eng_spd

engineSpeed field in LYNX API

Transport Refrigeration Unit Engine Speed

The following values are allowed:High, Low, Very Low, Very High

rpm
ign

switchKeyStatus field in LYNX API

Lcv switch key status

lcv_road_energy

roadEnergy field in LYNX API

Lcv road energy

kJ
lcv_standby_energy

StandByEnergy field in LYNX API

Lcv standBy Energy

kJ
lcv_pwr_mode

powerMode field in LYNX API

Lcv power mode

pwr_int

batteryVoltage field in LYNX API

The voltage of the Transport Refrigeration Unit's 12V battery

V
pwr_cur

batteryCurrent field in LYNX API

Battery Current (Device)

mA
1wire_temp[N]

oneWireTemp[NUM] field in LYNX API

One Wire temperature of the [N] sensor

°C
point_temp[N]

setpointTemp[N] field in LYNX API

Compartment [N] Setpoint Temperature

°C
bt_temp[N]

bluetoothTemp[N] field in LYNX API

Bluetooth temperature sensor [N]

°C
datacold_temp[0]

datacoldTemp[N] field in LYNX API

DataCOLD temperature sensor [N]

°C
ret_air_temp[N]

returnAirTemp[N] field in LYNX API

Compartment [N] Return Air Temperature

°C
supply_air_temp[N]

supplyAirTemp1 field in LYNX API

Compartment [N] Supply Air Temperature

°C
tenant_name


tenantName field in LYNX API

Asset Company Name

ctrl_sys_type

truControlSystemType field in LYNX API

Transport Refrigeration Unit - Control System Type

plate_number

licensePlateNumber field in LYNX API

Asset License Plate

sf_vers

truSoftwareVersion field in LYNX API


Transport Refrigeration Unit - Software Version

tru_model_num

truModelNumber field in LYNX API

Transport Refrigeration Unit - Model Number

operat_mode[N]

comp[N]OperatingMode field in LYNX API

Operating mode of Compartment [N]

fuel_lvl

fuelLevel field in LYNX API

Transport Refrigeration Unit Fuel Level

%
side_door

sideDoorOpen field in LYNX API

ndicates if the side door on the truck or trailer is open or not

rear_door

rearDoorOpen field in LYNX API

Indicates if the rear door on the truck or trailer is open or not

mileage

vehicleMileage field in LYNX API

Mileage of the unit at the time of the message

km
rssi

signalStrength field in LYNX API

Signal Strength

Contactez Wialon et atteignez les objectifs les plus ambitieux en télématique

Remplissez le formulaire pour commencer à travailler avec Wialon

Étape 1
Étape 2
Étape 3
Prénom*
Nom*
Entreprise*
Email*
Téléphone