| pwr_on | powerStatus field in LYNX API Transport Refrigeration Unit Power Status (On or Off)
 |  | 
                                            
                            | total_hours | switchOnHours field in LYNX API  The total accumulated hours that the Transport Refrigeration Unit has been turned on |  | 
                                            
                            | eng_hours | engineRunHours field in LYNX API The total accumulated hours that the Transport Refrigeration Unit has been running on its engine
 |  | 
                                            
                            | tru_status | truStatus field in LYNX API  
 Overall Status of the Transport Refrigeration Unit The following values are allowed:OFF, ON |  | 
                                            
                            | hours_standby | standByHours field in LYNX API The total accumulated hours that the Transport Refrigeration Unit has been running on stand by, or electric, power
 |  | 
                                            
                            | movement_status | movementStatus field in LYNX API Indicates if the unit is moving or not
 |  | 
                                            
                            | eng_power_mode | enginePowerMode field in LYNX API 
 Transport Refrigeration Unit Power Source (Engine or Standby) The following values are allowed:Standby, Engine |  | 
                                            
                            | eng_ctrl_mode | engineControlMode field in LYNX API 
 Transport Refrigeration Unit Control Mode The following values are allowed:Continuous, Start/Stop |  | 
                                            
                            | eng_spd | engineSpeed field in LYNX API 
 Transport Refrigeration Unit Engine Speed The following values are allowed:High, Low, Very Low, Very High | rpm | 
                                            
                            | ign | switchKeyStatus field in LYNX API Lcv switch key status
 |  | 
                                            
                            | lcv_road_energy | roadEnergy field in LYNX API Lcv road energy
 | kJ | 
                                            
                            | lcv_standby_energy | StandByEnergy field in LYNX API Lcv standBy Energy
 | kJ | 
                                            
                            | lcv_pwr_mode | powerMode field in LYNX API  Lcv power mode
 |  | 
                                            
                            | pwr_int | batteryVoltage field in LYNX API The voltage of the Transport Refrigeration Unit's 12V battery | V | 
                                            
                            | pwr_cur | batteryCurrent field in LYNX API Battery Current (Device)
 | mA | 
                                            
                            | 1wire_temp[N] | oneWireTemp[NUM] field in LYNX API One Wire temperature of the [N] sensor 
 | °C | 
                                            
                            | point_temp[N] | setpointTemp[N] field in LYNX API Compartment [N] Setpoint Temperature
 | °C | 
                                            
                            | bt_temp[N] | bluetoothTemp[N] field in LYNX API Bluetooth temperature sensor [N]
 | °C | 
                                            
                            | datacold_temp[0] | datacoldTemp[N] field in LYNX API DataCOLD temperature sensor [N]
 | °C | 
                                            
                            | ret_air_temp[N] | returnAirTemp[N]  field in LYNX API Compartment [N] Return Air Temperature
 | °C | 
                                            
                            | supply_air_temp[N] | supplyAirTemp1 field in LYNX API Compartment [N] Supply Air Temperature
 | °C | 
                                            
                            | tenant_name | 
 tenantName field in LYNX API Asset Company Name |  | 
                                            
                            | ctrl_sys_type | truControlSystemType field in LYNX API Transport Refrigeration Unit - Control System Type
 |  | 
                                            
                            | plate_number | licensePlateNumber field in LYNX API Asset License Plate
 |  | 
                                            
                            | sf_vers | truSoftwareVersion field in LYNX API 
 Transport Refrigeration Unit - Software Version |  | 
                                            
                            | tru_model_num | truModelNumber field in LYNX API Transport Refrigeration Unit - Model Number
 |  | 
                                            
                            | operat_mode[N] | comp[N]OperatingMode field in LYNX API Operating mode of Compartment [N]
 |  | 
                                            
                            | fuel_lvl | fuelLevel field in LYNX API  Transport Refrigeration Unit Fuel Level 
 | % | 
                                            
                            | side_door | sideDoorOpen field in LYNX API ndicates if the side door on the truck or trailer is open or not
 |  | 
                                            
                            | rear_door | rearDoorOpen field in LYNX API Indicates if the rear door on the truck or trailer is open or not
 |  | 
                                            
                            | mileage | vehicleMileage field in LYNX API Mileage of the unit at the time of the message
 | km | 
                                            
                            | rssi | signalStrength field in LYNX API Signal Strength
 |  |