Galileosky v 2.5

Galileosky v 2.5
Fabricante: Galileosky
Forum Discussion

Número de unidades

7
ON-LINE
20
TOTAL
Features Galileosky v 2.5:
  • Caixa preta
  • Suporte GLONASS
  • Envio de dados para vários servidores
  • Odômetro integrado
Supported in Wialon:
  • Acelerômetro
  • Sensores ADC
  • Conexão da câmera
  • Suporte para barramento CAN
  • Condução ecológica
  • Suporte Garmin
  • Gerenciamento remoto via GPRS
  • Identificação do motorista
  • Sensores digitais
  • Envio de dados por SMS
  • Gerenciamento remoto via SMS
  • Comunicação via TCP

The following data should also be added to Galileosky v 2.5 unit properties section of Wialon GPS tracking software :

Device type: Galileosky v 2.5
ID único: imei

Specify the following parameters in configuration software or configuration Galileosky v 2.5 for use in Wialon Hosting :

Porta do servidor: 21373

20 units of Galileosky v 2.5 device type are connected to Wialon Data Center. This represents 0% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
acc1 input ADC 5
acc2 Acceleration
acc Acceleration
accident_codeN Accident code N
accidentN The level of accident N
acc_trigger Acceleration status
accX X-axis acceleration

M/S2

accY Y-axis acceleration

M/S2

accZ Z-axis acceleration

M/S2

adcX Analog sensor, X - number of sensor
adcX_s Signed analog sensor, X - number of sensor
adc9 RS232 0
adc10 RS232 1
alarm_codeN Zone N alarm code
alarm_typeN Zone N alarm type
blast_air_tempN Zone N blast air temperature °C
braking_accel Braking

M/S2

canX Value of CAN, X - identifier of a message
course_accel Acceleration

M/S2

dinN Refrigerator's digital input N value
ds1923_humidityX humidity sensor DS1923, X - number of sensor %
ds1923_tempX Temperature sensor DS1923, X - number of sensor °C
evap_tempN Zone N evaporator temperature °C
fms_spn_1611

SAE J1939 SPN 1611. Drive recognize

fms_spn_1612

SAE J1939 SPN 1612. Driver 1 working state

fms_spn_1613 SAE J1939 SPN 1613. Driver 2 working state
fms_spn_1614

SAE J1939 SPN 1614. Overspeed

fms_spn_1615

SAE J1939 SPN 1615. Driver 1 card

fms_spn_1616

SAE J1939 SPN 1616. Driver 2 card

fms_spn_1617

SAE J1939 SPN 1617. Driver 1 time rel. states

fms_spn_1618

SAE J1939 SPN 1618. Driver 2 time rel. states

fms_spn_1619

SAE J1939 SPN 1619. Direction indicator

fms_spn_1620

SAE J1939 SPN 1620. Tachograph performance

fms_spn_1621

SAE J1939 SPN 1620. Handling information

fms_spn_1622

SAE J1939 SPN 1621. Tachograph event

fuel_level Fuel level in the tank %
gprs_answer Response device
gps_mileage Total mileage according to the GPS/GLONASS modules Meter
gsm_status GSM signal quality
hdop Horizontal accuracy
hours_counterN Counter N hours till service h
hours_electric Motohours. Electric h
hours_engine Motohours. Engine h
hours_standby Motohours. Standby h
hours_switch Motohours. Switch h
hours_vehicle Motohours. Vehicle h
ibutton_code Identification number of the first key iButton
ibuttons Ibutton keys status
omni_tmp_X Omnicom sensor, X - number of sensor
pressX_pci_data Pressure in atm, X - number of sensor
pressX_status_battery Sign of low battery charge the internal battery, X - number of sensor
pressX_status_error Reason parcel packet from the sensor, X - number of sensor
pressX_tmp Temperature, X - number of sensor
pwr_ext Voltage of external power supply Volt
pwr_int Power supply internal battery Volt
refr_type Refrigerator unit type. 1 – DataCOLD, 2 – ThermoKing, 3 – Mitsubishi
return_air_tempN Zone N return air temperature °C
rs485ex_X_lvl Fuel sensor connected via rs485
rs485ex_X_tmp Temperature sensor connected via rs485 °C
rs485_fls02 Fuel sensor connected via rs485
rs485_fls12 Fuel sensor connected via rs485
rs485_fls22 Fuel sensor connected via rs485
rs485tmp_X Temperature sensor connected via rs485, X - number of sensor
set_tempN Zone N set temperature
soft Current version of firmware
statusN Zone N status
taho Engine speed
temp_aqua Coolant temperature °C
temp_int temperature of the terminal °C
temp_sensorN Temperature sensor N value °C
tempX Temperature sensor, X - number of sensor °C
trailer_id Identification number of the second key iButton
trailer_id_code Identification number of the second key iButton as decimal
turn_accel Acceleration on the turn

M/S2

valid Valid of coordinates (0-valid, 1-invalid, 2-LBS coordinates, 15-GPS module is off )
vertical_accel Vertical acceleration

M/S2

vib_N

The relative intensity of vibration analysis with N unique identifier of a characteristic feature

user_d User data
taho_type Tachograph type
taho_state

Tachograph connection state:
0 - not connected
1 - not authorised
2 - authorised

taho_mode

Сurrent mode of the tachograph:
0 - normal mode
1 - control mode
2 - calibration mode
3- enterprise mode

taho_speed Vehicle speed km/h
taho_trip Trip distance
taho_flags

Flags of the tachograph status:
0 - igntion
1 - switched ground (for ADR)
2 - special condition of "ferry / train"

taho_dN_activity

Current activity of the N driver:
0 – rest
1 – availability
2 – work
3 – drive

taho_dN_cardtype

Card type of the N driver:
1 – Driver card
2 – Workshop card
3 – Controller card
4 – Company card

taho_dN_activ_tm The time spent in the current mode. min
taho_dN_driv_tm Accumulated driving time in a day. min
taho_dN_restl_tm Сontinuous driving time since the last rest. min
taho_dN_card_num Card number.
wheel_tempN Temperature in the wheel with N index °C
rec_sn Number of an archive record
can_r#

Tag value

For tag with value range (HEX) 0xC4 - 0xD2 , 0xD6 - 0xDA, 0xDB - 0xDF

# = Tag number (DEC) - 196

can8bitr#

Tag value

For tag with value range (HEX) 0xA0 - 0xAF

# = Tag number (DEC) - 144

can16bitr#

Tag value

For tag with value range (HEX) 0xB0 - 0xB9

# = Tag number (DEC) - 144

can32bitr#

Tag value

For tag with value range (HEX) 0xF0 - 0xF9

# = Tag number (DEC) - 144

User manual for Galileosky v 2.5

More devices from the manufacturer

Entre em contato com a Gurtam e alcance seus mais ambiciosos objetivos através da telemática

Preencha um formulário de solicitação para começar

PASSO 1
PASSO 2
PASSO 3
Primeiro nome*
Sobrenome*
Empresa*
E-mail*
Telefone