Megastek GVT-430

Megastek GVT-430
Forum Discussion

Número de unidades

0
ON-LINE
0
TOTAL
Features Megastek GVT-430:
  • 3G
  • Caixa preta
Supported in Wialon:
  • Sensores ADC
  • Gerenciamento remoto via GPRS
  • Sensores digitais
  • LBS
  • Botão de alarme
  • Comunicação via TCP

The following data should also be added to Megastek GVT-430 unit properties section of Wialon GPS tracking software :

Device type: Megastek GVT-430
ID único: imei

Specify the following parameters in configuration software or configuration Megastek GVT-430 for use in Wialon Hosting :

Porta do servidor: 21513

0 units of Megastek GVT-430 device type are connected to Wialon Data Center. This represents 0% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
bds_sat The number of BDS satellite used to fix
glonass_sat The number of GPS satellite used to fix
hdop Horizontal dilution of precision
gprsf

‘R’ - GPRS data is a real-time data
‘S’ - GPRS data is a stored data

mileage Mileage km
mcc Mobile country code
mnc Mobile network code
lac Location area code
cell_id Cell ID
gsm GSM signal strength
charging_flag

Charging flag:
0 - not charging
1 - charging

belt_status

Belt status:
0 - no belt is connected
1 - first belt is connected
2 - second belt is connected
3 - first and second belts are all connected

battery Battery percent %
event_type

Alert event type:
Restart - Device restart by hardware
PowerOn - Device power on by software
PowerOff - Device power off by software
Sos - SOS emergency alert
Timer - Sending GPRS data by interval
CallForSms - Sending SMS by making a call (only for SMS)
LowBattery - Low battery alert
GeoX(GeoName) In - Going into the geo-fence, ‘X’ is the sequence of geo-fence; GeoName - name user set for geo-fence
GeoX(GeoName) Out - Going out of the geo-fence, ‘X’ is the sequence of geo-fence; GeoName - is the name user set for geo-fence
BeltOn - Belt is connected
BeltOff - Belt is disconnected
LocRequest - Real-time location request
Error - Alert type error

inN Digital input status with N number
outN Digital output status with N number
adc1 External voltage
adc2 Analog input 2
adc3 Analog input 3
temp_1 Detected value of temperature sensor °C
temp_2 Detected value of temperature sensor 2 °C
rfid RFID information

More devices from the manufacturer

Entre em contato com a Gurtam e alcance seus mais ambiciosos objetivos através da telemática

Preencha um formulário de solicitação para começar

PASSO 1
PASSO 2
PASSO 3
Primeiro nome*
Sobrenome*
Empresa*
E-mail*
Telefone