Pengsent FM02-2G

Pengsent FM02-2G
Fabricante: Pengsent

Número de unidades

0
ON-LINE
1
TOTAL
Features Pengsent FM02-2G:
  • 2G
Supported in Wialon:
  • Comunicação via TCP
  • Comunicação via UDP

The following data should also be added to Pengsent FM02-2G unit properties section of Wialon GPS tracking software :

Device type: Pengsent FM02-2G
ID único: custom

Specify the following parameters in configuration software or configuration Pengsent FM02-2G for use in Wialon Hosting :

Porta do servidor: 22587

1 units of Pengsent FM02-2G device type are connected to Wialon Data Center. This represents 0% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
encoding

0X01: UTF-8
0x02: ASCII;

odometer Odometer
status_code

Report status: Status code
0x00 Upload in fixed time interval
0x14 Enter Geofence
0x15 Exit Geofence
0x1A Battery low power
0x1B Overspeed

mcc Mobile Country Code
visible_sats Visible satellites
gps_time_status GPS is Real Time or Reupload
battery Fuel level battery value
status_reg_content Report status: Trigger content
inputs Input's Status, Bit 1-4: Door button status (1/0 Door Open/Close), Bit 5-8: Tamper button status (1/0 Removal/Installation) 0xff: Failed to get button status
door Door status
content the command response content
voltage

Voltage degree 0-6:
0: Lowest power and power off
1: No enough power to dial a call or send messages.
2: Low power and alarm
3: Lower power but can work normally
3~6: Work in good condition

status_trig_time1 Report status: Trigger time
sats Number of satellites
temp Fuel temperature
lac Location Area Code
cell_id Cell Tower ID
sequence_num Sequence Number
sensor_percent Fuel level in percent
boot_reason Boot Reason
server_flag It refers to the data to send (by the coding format);
gsm_signal_csq GSM Signal CSQ
imsi imsi number
battery_vol Battery Voltage
alarm_status

Alarm status:
0: Normal
1: Shock Alarm
2: Power Cut Alarm
3: Low Battery Alarm
4: SOS

time Time stamp
iccid iccid number
pwr_int Battery voltage(mV)
alarm

Alarm status:
0: normal
1: SOS
2: Power Cut Alarm
3: Vibration Alarm
4: Fence In Alarm
5: Fence Out Alarm
6: Over-speed Alarm
9: Moving Alarm

acc ACC Status. ACC low: 0, ACC high: 1
rssi LBS Main Cell Tower, rssi
sensor_type

Sensor type:
0: BLE type;
1: RS485 type.

mnc Mobile Network Code
imei imei number
gsm GSM signal strength degree
pwr_ext Voltage level
hdop HDOP
mileage Mileage statistics

More devices from the manufacturer

Faça sua empresa crescer com a gente