Syrus

Syrus
Fabricante: DCT
Forum Discussion

Número de unidades

299
ON-LINE
666
TOTAL
Supported in Wialon:
  • Sensores ADC
  • Gerenciamento remoto via GPRS
  • Sensores digitais
  • Gerenciamento remoto via SMS
  • Comunicação via TCP

The following data should also be added to Syrus unit properties section of Wialon GPS tracking software :

Device type: Syrus
ID único: serial

Specify the following parameters in configuration software or configuration Syrus for use in Wialon Hosting :

Porta do servidor: 20423

666 units of Syrus device type are connected to Wialon Data Center. This represents 0.03% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
io_a

Bitwise parameter:
bit0: Ignition (1=ACTIVE, 0=INACTIVE)
bit1: Main Power Source (1=EXT-PWR, 0=BACKUP-BATTERY)

io_b

Bitwise parameter:
bit0: Output 1 (1=ACTIVE, 0=INACTIVE)
bit1: Output 2 (1=ACTIVE, 0=INACTIVE)

io_c

Bitwise parameter:
bit0: Input 1 (1=ACTIVE, 0=INACTIVE)
bit1: Input 2 (1=ACTIVE, 0=INACTIVE)
bit2: Input 3 (1=ACTIVE, 0=INACTIVE)

vo Current value of the virtual odometer
events

Event index. 0-99. If event index equals to 31, then message will be registered as alarm

keep_alive_count Keep-alive messages counter. Registered if checkbox "Keep alive messages counter" is enabled in the Device configuration in unit properties
cntrN_command

Counter N command. Refer to "GC - Counters, Timers, Distancers" in Syrus documentation.
N - counter index

cntrN_flag

Counter N recycle flag. Refer to "GC - Counters, Timers, Distancers" in Syrus documentation.
N - counter index

cntrN_val1

Counter N threshold increment. Refer to "GC - Counters, Timers, Distancers" in Syrus documentation.
N - counter index

cntrN_val2

Counter N data increment value. Refer to "GC - Counters, Timers, Distancers" in Syrus documentation.
N - counter index

xp2

The status of signal "XP2" (XP1 - XP2: Outputs. Status is 1 when the corresponding output is on)

pwr_int

Voltage level of the battery.

Volts
ix1_ios_expander

I/Os expander connection state

1=Connected
0=No connected

ix1_outputs_circuit

I/Os all outputs short circuit indicator:
1=Short circuit detected
0=Short circuit not detected

ix2_ext_power

External power 1:
1=Connected
0=No connected

ix2_ignition

General inputs state. Ignition
1=On
0=Off

ix3_inN

Embedded inputs state Input N (N=1,2,3)

1=Active
0=Inactive

ix4_outN

Embedded outputs state Output N (N=1,2)

1=Active
0=Inactive

ix5_outputs_circuit

Short circuit on embedded outputs 1 or 2:
1=Short circuit detected
0=Short circuit not detected

ce

Value of ignition counter

cl Value of idle counter.
cs

Value of over speed counter.

cv_N

Counter N Value.

accel

Instant acceleration measured

Miles per hour per seconds
low_battery

Low battery equals to 1 when device sends message with event id=55. Otherwise, low_battery equals 0.

More devices from the manufacturer

Entre em contato com a Gurtam e alcance seus mais ambiciosos objetivos através da telemática

Preencha um formulário de solicitação para começar

PASSO 1
PASSO 2
PASSO 3
Primeiro nome*
Sobrenome*
Empresa*
E-mail*
Telefone