ZTEWelink VM6200S

ZTEWelink VM6200S
Fabricante: Gosuncn
Forum Discussion

Número de unidades

0
ON-LINE
2
TOTAL
Features ZTEWelink VM6200S:
  • 4G/LTE
  • Caixa preta
  • Odômetro integrado
  • Ponto de acesso Wi-Fi
Supported in Wialon:
  • Acelerômetro
  • Suporte para barramento CAN
  • Gerenciamento remoto via GPRS
  • Sensores digitais
  • Comunicação via TCP

The following data should also be added to ZTEWelink VM6200S unit properties section of Wialon GPS tracking software :

Device type: ZTEWelink VM6200S
ID único: imei

Specify the following parameters in configuration software or configuration ZTEWelink VM6200S for use in Wialon Hosting :

Porta do servidor: 21354

2 units of ZTEWelink VM6200S device type are connected to Wialon Data Center. This represents 0% of all OBD trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
pos_source

Position source:
0 - GPS
1 - GSM

vdop VDOP
pdop PDOP
hdop HDOP
fault_code_#

DTC code,
# = 1,2,3... (number of DTC code in the message)
(DTC)

state_code_#

The state of standard OBDII fault code (corresponds to fault_code_#):
0x00 - Current fault code
0x01 - Pending fault code
0x02 - Permanent fault code
(DTC)

data_type

Type of event:
0000 - Trip summary
0001 - Ignition on
0002 - Ignition off

0100 - Sudden acceleration
0101 - Sudden deceleration
0102 - Sharp turn
0103 - Exceed idle
0104 - Driving tired

0300 - VIN code
0301 - vehicle data flow

0400 - DTC code

ign

Ignition.
0 - Off
1 - On

mileage

Trip mileage
(Trip summary)

m
stat_source

Statistics source for mileage parameter:
0x0-OBD
0x1-GPS
(Trip summary)

drv_fuel_consumption

Driving fuel consumption
(Trip summary)

ml
max_speed

Maximum speed
(Trip summary)

km/h
idle_time

Idle time
(Trip summary)

s
idle_fuel_consumption

Idle fuel consumption
(Trip summary)

ml
n_rapid_accel

Number of rapid accelerations
(Trip summary)

n_rapid_decel

Number of rapid deceleraion
(Trip summary)

n_rapid_sharp_turn

Number of rapid sharp turn
(Trip summary)

accum_mileage

Historical total mileage
(Trip summary)

m
accum_fuel_consumption

Historical total fuel consumption
(Trip summary)

ml
accum_drv_time

Historical total driving time
(Trip summary)

s
type_ignon

How to judge the ignition state:
0x00 - RPM > 100
0x01 - Time of ignition on > 0
(Ignition on)

type_ignoff

How to judge the ignition state:
0x00- RPM is 0
0x01- Time of ignition on is 0
0x02- RPM is constant
0x03- Time of ignition is constant
0x04-Communication of OBD is unsuccessful
(Ignition off)

speed_before

Speed before acceleration
(Sudden acceleration, Sudden deceleration)

km/h
speed_after

Speed after acceleration
(Sudden acceleration, Sudden deceleration)

km/h
accel

Acceleration
(Sudden acceleration, Sudden deceleration)

m/s^2
accel_turn

Acceleration
(Sharp turn)

vin

VIN
(VIN code)

Device needs 3DES encryption key to be set in configuration window.


More devices from the manufacturer

Entre em contato com a Gurtam e alcance seus mais ambiciosos objetivos através da telemática

Preencha um formulário de solicitação para começar

PASSO 1
PASSO 2
PASSO 3
Primeiro nome*
Sobrenome*
Empresa*
E-mail*
Telefone