Globalstar SmartOneC

Globalstar SmartOneC
Fabricante: Globalstar
Forum Discussion

Número de unidades

162
ON-LINE
624
TOTAL
Features Globalstar SmartOneC:
  • Boîte à mémoire
Supported in Wialon:
  • Capteurs numériques
  • Communication via TCP

The following data should also be added to Globalstar SmartOneC unit properties section of Wialon GPS tracking software :

Device type: Globalstar SmartOneC
ID único: custom

Specify the following parameters in configuration software or configuration Globalstar SmartOneC for use in Wialon Hosting :

Porta do servidor: 22020

624 units of Globalstar SmartOneC device type are connected to Wialon Data Center. This represents 0.47% of all Asset trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
input_state

These bits reflect the state of the inputs and indicate which one, if any, triggered an Input Status Changed message. Bit 0: Input 1 change: 0 = Did not trigger message, 1 = Triggered message. Bit 1: Input 1 state: 0 =
Closed, 1 = Open Bit 2: Input 2 change: 0 = Did not trigger message, 1 = Triggered message Bit 3: Input 2 state: 0 = Closed, 1 = Open.

msg_sub_type

Message sub-type code.

vibr

Value 1 = Unit is in a state of vibration. Value 0 = Unit is not in a state of vibration.

gps_fix_2d

Value 1 = GPS data reported is from a 2D fix. (Only 3 satellites were used in the fix.) Value 0 = GPS data reported is from a 3D fix.

motion

Value 1 = Device was In-Motion when the message was transmitted. Value 0 = Device was At-Rest when the message was transmitted.

num_tries

Number of Transmissions (1 to 15 Transmissions)

min_trans_interval

Minimum Interval between transmission attempts ( 5 second resolution) Default is 300 seconds

max_trans_interval

Maximum Interval between transmission attempts, Default is 600 seconds

gps_mean_search_time

Unsigned binary count in seconds for mean GPS search to acquire

gps_fails

Unsigned binary count of failed GPS attempts since last Diagnostic message

alarm Alarm Statistics
alarm1_count Alarm2 since last message (b7=0) / accum hours (b7=1)
alarm2_count

Alarm3 since last message (b7=0) / accum hours (b7=1)

transmissions Transmissions since last statistics message
input№_undesired_state_time

Accumulated time that Input 1 has been in its undesired state with a resolution of 10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as a value of 12, etc. This resolution results in a rollover rate of a total time accumulation of approximately 1.25 years. (OxFFFF means that Input 1 Accumulate has been turned off)

vibration_time

Accumulated time that the SMARTONE has been in a State of Vibration with a resolution of 10 minutes. For example: 1 hour would be represented as a value of 6, 2 hours as a value of 12, etc. This resolution results in a rollover rate of a total time accumulation of approximately 1.25 years. (OxFFFF means that Input 1 Accumulate has been turned off)

input№_switches_number

The total number of openings or closings of input 1 as selected by the user. (OxFF means that Input 1 Accumulate has been turned off)

transms_num

Number of transmissions per burst.

bat

Battery Condition. 0 = Good battery. 1 = Replace Battery

gps

GPS Subsystem Fault. 0 = GPS system OK. 1 = Fault.

transmt

Transmitter Subsystem Fault. 0 = Transmitter OK. 1 = Fault.

sched

Scheduler Subsystem Fault. 0 = OK. 1 = Fault.

More devices from the manufacturer

Entre em contato com a Gurtam e alcance seus mais ambiciosos objetivos através da telemática

Preencha um formulário de solicitação para começar

PASSO 1
PASSO 2
PASSO 3
Primeiro nome*
Sobrenome*
Empresa*
E-mail*
Telefone