Queclink GV65 Plus

Queclink GV65 Plus
Forum Discussion

Number of units

34
Online
83
Total
Features Queclink GV65 Plus:
  • Blackbox
  • GLONASS support
Supported in Wialon:
  • ADC sensors
  • Remote management via GPRS
  • Driver identification
  • Digital sensors
  • LBS
  • Remote management via SMS
  • Communication via TCP
Can be supported upon request:
  • SMS sending of data
  • Communication via UDP

The following data should also be added to Queclink GV65 Plus unit properties section of Wialon GPS tracking software :

Device type: Queclink GV65 Plus
Unique ID: imei

Specify the following parameters in configuration software or configuration Queclink GV65 Plus for use in Wialon Hosting :

Server port: 20981

83 units of Queclink GV65 Plus device type are connected to Wialon Data Center. This represents 0% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
battery The current volume of the backup battery %
call_number The phone number of the incoming call which triggers the report message
curr_hour_meter The current hour meter count h
curr_mileage The current mileage km
ext_gps_ant

External GPS antenna status:
0 - is working
1 - is detected in open circuit state
3 - is in unknown state

fuel_level The fuel level
gps_acc GPS accuracy
gps_signal_status

GPS signal status:
0 - lost GPS signal or no successful GPS fix
1 - GPS signal recovered and successful GPS fix

harsh_behavior

Harsh behavior:
0 - harsh braking behavior
1 - harsh acceleration behavior

harsh_speed_level

The speed level of which the harsh behavior is detected:
0 - unknown speed
1 - low speed
2 - medium speed
3 - high speed

h_m_count The total hour meter count h
hour_meter_count The total hour meter count h
idling The time that the vehicle has been in idling status s
ign Ignition state: 0 - off, 1 - on
ign_off_duration Duration since last time the ignition is off s
ign_on_duration Duration since last time the ignition is on s
input_id ID of the input to which the fuel sensor is connected to, 0 means connected with serial port
inputN

The current logical status of the input port number N:
0 - is disable status
1 - is enable status

jamming_status

The current Jamming status of the device.
1 - quit the jamming
2 - enter the jamming

mileage The total mileage km
msg_type The message ID of HEX format report
pwr_ext The voltage of the external power supply V
pwr_int The voltage of the backup battery. The value of this field is only valid when the external power is not connected V
report_type The message type of ASCII format report
motion_state

The current motion state of device:
16 - Tow
1A - Fake Tow
11 - Ignition Off Rest
12 - Ignition Off Motion
21 - Ignition On Rest
22 - Ignition On Motion
41 - Sensor Rest
42 - Sensor Motion

tempN The temperature sensor number N value °C
total_hour_meter The total hour meter count h
total_mileage The total mileage km

More devices from the manufacturer

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First name*
Last name*
Company*
Email*
Phone