Queclink GV350M

Queclink GV350M
Forum Discussion

Number of units

920
Online
2785
Total
Features Queclink GV350M:
  • 4G/LTE
  • Blackbox
Supported in Wialon:
  • ADC sensors
  • Digital sensors
  • LBS
  • Communication via TCP
  • Communication via UDP

The following data should also be added to Queclink GV350M unit properties section of Wialon GPS tracking software :

Device type: Queclink GV350M
Unique ID: imei

Specify the following parameters in configuration software or configuration Queclink GV350M for use in Wialon Hosting :

Server port: 21709

2785 units of Queclink GV350M device type are connected to Wialon Data Center. This represents 0.12% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
dev_type

Queclink device type
*HEX mode only

proto_ver

Queclink protocol version
*HEX mode only

fw_ver

Firmware version
*HEX mode only

battery

Battery level, 0-100

pwr_ext

External power source voltage

adc_mode

Analog Input Mode

adc1

Analog Input 1 voltage

din_status

Digital Input Mode
Ignition Detection 0x01
Digital Input1 0x02
Digital Input2 0x04
Digital Input3 0x08

dout_status

Digital Output Mode
Digital Output1 0x01
Digital Output2 0x02
Digital Output3 0x04

motion_status
phone_number
ign_dur
can_group_id
can_alarm_mask_1
can_alarm_mask_2
can_alarm_mask_3
ibutton
ibutton_auth
geo_id
ges_enabled
ges_mode
ges_radius
ges_dt
jamming_cw
jamming_gps
upc_cmd_id
upc_result
url
onewire[i]_id
onewire[i]_type
onewire[i]_data
fuel_sensor[i]_type
fuel_sensor[i]_id
fuel_sensor[i]_percent
fuel_sensor[i]_volume
pwr_int
upd_code
upd_retry
idle_dt
gps_signal_status
wave1_out_id
wave1_out_active
temp_alarm_id
temp_status
temp_device_id
temp_device_data
roaming_state
fuel_input_id
fuel_level_last
fuel_level_current
mup_event
phl_mask
fuel_sensor_type
fuel_hw_fault_code
ufs_code
file_name
cfu_code
mcc
mnc
lac
cell_id
curr_mileage

Current Trip Mileage
*HEX mode only

total_mileage

Total Mileage
*HEX mode only

curr_hourmetercount

Current Trip Hour Meter Count (accumulative ignition time)
*HEX mode only

total_hourmetercount

Total Hour Meter Count (accumulative ignition time)
*HEX mode only

fri_discard_no_fix
resp_report_mask
ign_dt
igf_dt
bat_status
iccid
csq_ber

CSQ BER,0-7/99

daylight_saving
time_zone
sens_proto_ver
sens_sw_ver
sens_hw_ver
can100_sw_ver
can100_serial
adcf fuel level in percent

More devices from the manufacturer

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First name*
Last name*
Company*
Email*
Phone