Supported in Wialon:
  • Communication via TCP

The following data should also be added to Suntech ST400 unit properties section of Wialon GPS tracking software :

Device type: Suntech ST400
Unique ID: custom

Specify the following parameters in configuration software or configuration Suntech ST400 for use in Wialon Hosting :

Server port: 21599

3 units of Suntech ST400 device type are connected to Wialon Data Center. This represents 0% of all Asset trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
sw_ver

Number of the released Software Version

model

1: ST400

cell_id

Information of Cell ID

mnc

Information of Mobile Network Code

mcc

Information of Country Code

rx_level

Information of RX Level

lac

Information of Location Area Code

ta

Information of Timing Advance

online

1, if the report is sent immediately;

0, if the report is sent from the memory

pwr_int

Voltage level of Backup Battery

V
msg_no

Message number

mode

1: Normal Mode

2: Emergency Mode by GPRS Command

3: Emergency Mode by RF Command

4. Emergency Mode by Jammer Detection

5: Backup battery is under threshold

6: Carton Package is opened

For ALT messages:

1 Alert for Jamming is Detected
2 Alert for Carton Box is Opened

serial_no Serial number of RF device which is in Emergency mode.
dev_type

Type of Device

0: Presence Check Device, Adjunct RF Device, Presence Keychain

1: Isca, Long Life Isca, Presence Check Device, V2 Long Life Isca

2: RF Searching Device, Radis Base Station, Searching Device for Drone

3: Tracking Device with RF, Trailer RF Device

msg_type

Type of Message

0: Emergency Message with GPS coordinates

3: Emergency Message without GPS coordinates.

lat

Latitude of RF Device which is in emergency mode

0.0 if RF device does not have GPS

lon

Longitude of RF Device which is in emergency mode

0.0 if RF device does not have GPS

box_stat

0: Box is opened

1: Box is closed

volt_rf_dev

Battery Voltage of RF Device which is in emergency mode. 0x0 represents 3.2 volts or less.

0xF represents fully charged. Otherwise each step has 0.0667 volts of difference.

rssi

RSSI in dBm received from RF Device which is in emergency mode. -255 means RSSI is not available.

dBm