MVT600

Number of units

156
Online
284
Total

The following data should also be added to MVT600 unit properties section of Wialon GPS tracking software :

Device type: MVT600
Unique ID: imei

Specify the following parameters in configuration software or configuration MVT600 for use in Wialon Hosting :

Server port: 20259

284 units of MVT600 device type are connected to Wialon Data Center. This represents 0.01% of all AVL Hardware connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
text

"err_flag" value of this parameters means reply on command for LED display:
00 - OK
02 — CRC verification error
03 — Unknown command string
04 — The update file length is inconsistent.
05 — The factory logo of the update file is inconsistent.
06 — Update state exited.
07 — The LED display is not connected.
08 — The update file package and request package are inconsistent.
09 — Update timeout
10 — Flash update error
15 — The serial port data length is inconsistent.
16 — Try to delete information that does not exist.

Note: It is possible to get photos from your camera.

To send a message to the LED display you need to create a command of type "custom_msg" and use the following command text:

send_led_msg,1|0|00:00:00|0|0|000101000000,Hello

Where:

send_led_msg - prefix for LED display message;

, - separator

1|0|00:00:00|0|0|000101000000 - parameters ( | - separator for parameters):

1) Playing level:

0: normal. Instant information will be played after the existing information playing is finished.
1: urgent. Interrupt the existing information playing, and play instant information immediately.
2) How to exit instant state
0: By exit command
1: By instant end time
2: By instant playing time
3: By number of instant cycle times

4: By scheduled playing

3) Instant end time or life cycle: If the instant state exits by 1, the parameter is End
Time; if the instant state exits by 4, the parameter is Life Cycle.

4) Instant playing time: The unit is second.

5) Number of instant cycle times

6) Parameter displayed PPPPPP:

First P: font. 00 – thin font. 01 – bold font.

Second P: 01 (default)

Third P: action. Move left: 01; Move up: 03; Move down: 04; Retain: 05.

Fourth P: speed. 00: 10 bytes/s; 01: 8 bytes/s; 02: 5 bytes/s; 03: 4 bytes/s; 04: 2 bytes/s.

Fifth P: stop time. 00. Unit: second.

Sixth P: stop mode. 00: paging stop; 01: last page stop.

, - separator

Hello - message text.

Note: Before sending new message to the LED display you need to send command of type "custom_msg" and use the command text "delete_led_msg" if you chose "How to exit instant state by exit command"