JM-LG01

JM-LG01
Manufacturer: Jimi IoT (Concox)
Forum Discussion

Number of units

20
Online
755
Total
Features JM-LG01:
  • Blackbox
  • Magnetic mounting

The following data should also be added to JM-LG01 unit properties section of Wialon GPS tracking software :

Device type: JM-LG01
Unique ID: imei

Specify the following parameters in configuration software or configuration JM-LG01 for use in Wialon Hosting :

Server port: 21905

755 units of JM-LG01 device type are connected to Wialon Data Center. This represents 0.57% of all Asset trackers connected.

Below chart represents the dynamic of connections in the last 30 days:

Parameter name Description Units
voltage Voltage level
gsm

GSM Signal Strength:

  • 0x00: no signal;
  • 0x01: extremely weak signal;
  • 0x02: weak signal;
  • 0x03: good signal;
  • 0x04: strong signal.

serial Serial number of data sent
mcc Mobile Country Code
mnc Mobile Network Code
lac Location Area Code
cell_id Cell Tower ID
acc ACC Status. ACC low: 00, ACC high: 01
data_mode

GPS data upload mode

  • 0x00 Upload by time interval
  • 0x01 Upload by distance interval
  • 0x02 Inflection point upload
  • 0x03 ACC status upload
  • 0x04 Re-upload the last GPS point when back to static.
  • 0x05 Upload the last effective point when network recovers.

gps_real_up 0x00 Real time upload 0x01 Re-upload
rssi

Signal level of community,range 0x00~0xFF,

  • 0x00 Weakest signal
  • 0xFF Strongest signal

tmng_adv Value= “Actual time of signal from Mobile Station to Location base”-“Time of signal from Mobile Station to Location base supposed the distance is 0”
voltage_lvl

Voltage Level:

  • 0 - No Power (shutdown)
  • 1 - Extremely Low Battery (not enough for calling or sending text messages, etc.)
  • 2 - Very Low Battery (Low Battery Alarm)
  • 3 - Low Battery (can be used normally)
  • 4 - Medium
  • 5 - High
  • 6 - Very High

alarm_state

Alarm information

0 - normal
1 - SOS
2 - Power cut alarm
3 - Vibration alarm
4 - Enter fence alarm
5 - Exitfence alarm
6 - Over speed alarm
9 - Vibration alarm
10 - Enter GPS dead zone alarm
11 - Exit GPS dead zone alarm
12 - Power on alarm
13 - GPS First fix notice
14 - Low battery alarm
15 - Low battery protection alarm
16 - SIM change notice
17 - Power off alarm
18 - Airplane mode alarm
19 - Disassemble alarm

language

Language:
1 - Chinese
2 - English

More devices from the manufacturer

Contact Wialon and achieve the most ambitious goals with telematics

Fill out a request form to get started with Wialon

Step 1
Step 2
Step 3
First name*
Last name*
Company*
Email*
Phone